        Differential pressure transmitter Single crystal silicon pressure transmitter Electromagnetic flowmeter Capacitive pressure transmitter High precision pressure transmitter Intelligent pressure switch Diffused silicon pressure transmitter Flow switch Intelligent pressure transfer controller Thermometer

        Pressure transmitter


        BXY6001 Differential Pressure

        Product code

         

        Overview

        Product quotationProduct consulting

        Product introduction


        BXY6001 Differential Pressure Remote Transmission Transmitter
        1 Application
        The diaphragm box of the differential pressure remote transmitter is used to prevent the medium in the pipeline from directly entering the pressure sensor component of the differential pressure transmitter. It uses silicone oil and other filling liquids to transmit pressure between the transmitter and it.
        The BXY6001 differential pressure remote transmitter is used to measure the liquid level, density, pressure, and flow rate of liquids, gases, or vapors, and then convert it into a 4-20mADC HART current signal output. BXY6001 can also communicate with RST375 handheld terminals or RSM100 Modems for parameter setting, process monitoring, etc. The measurement range of BXY6001 differential pressure remote transmitter (when not relocated) is 0-1kPa~2MPa, and the rated pressure of the remote flange is 1.6/4MPa, 6.4MPa, 10MPa, 150psi, 300psi, or 600psi, respectively.
        2 Working principle
        The BXY6001 differential pressure remote transmission transmitter consists of a BXY6001 series differential pressure transmitter and a welded and installed capillary remote transmission flange. Its working principle is the same as the BXY6001 series differential pressure transmitter (refer to the technical specifications of the BXY6001 series differential pressure transmitter), but the pressure transmission path is slightly different: the pressure acting on the remote flange side first passes through the diaphragm and filling liquid on the remote flange, then through the capillary, and finally reaches the corresponding positive and negative sides of the measurement sensor.
        3 inputs
        Measurement parameters: differential pressure, liquid level
        Measurement range
        Lower limit value: from -100% URL (continuously adjustable)
        Upper limit value: to+100% URL (continuously adjustable)
        Range
        Table 1 Comparison Table of Range Code and Range Range Relationship


        Range code

        minimum range

        maximum range

        Rated pressure (maximum)

        B

        1kPa

        6kPa

        Rated pressure of remote transmission flange

        C

        4kPa

        40kPa

        D

        25kPa

        250kPa

        E

        200kPa

        2MPa

        Table 2 Comparison Table of the Relationship between Remote Transmission Flange and Minimum Range

        Level flange

        Nominal diameter

        minimum range

        Unilateral remote transmission

        Bilateral remote transmission

        Flat type

        DN 50/2”

        10kPa

        10kPa

        DN 80/3”

        6kPa

        1kPa

        DN 4”

        6kPa

        1kPa

        plug-in

        DN 50/2”

        16kPa

        16kPa

        DN 80/2”

        6kPa

        1kPa

        DN 4”

        6kPa

        1kPa

        The minimum range of the remote transmitter should be the larger value of the minimum range in Table 1 and Table 2. The adjusted range shall not be less than the minimum range. The maximum range of the remote transmitter should be the minimum of the maximum range of the transmitter body and the rated pressure of the liquid level flange.
        4 outputs
        output signal
        2-wire system, 4-20mADC HART output, digital communication, with HART protocol loaded on 4-20mADC signal.
        Output signal limit: Imin=3.9mA, Imax=20.mA
        Alarm current (mode can be set)
        Low alarm mode (minimum): 3.7 mA
        High alarm mode (maximum): 21 mA
        No alarm mode (hold): maintain the effective current value before the fault
        Alarm current standard setting: high alarm mode
        5 Response time
        The damping constant of the amplifier component is 0.1s; The time constant of the sensor and remote flange is 0.2-6s, depending on the sensor's range, range ratio, capillary length, and viscosity of the filling liquid. The additional adjustable time constant is 0.1~60s.
        6 General conditions
        6.1 Installation conditions
        The transmitter body can be directly fixed in any position. The optimal state is to keep the process flange axis in a vertical position, and the positional deviation will result in a correctable zero offset. The electronic watch case can rotate up to 360 °, and the positioning screw can fix it in any position.
        The remote flange is connected to a matching flange that complies with ANSI/DIN standards. The matching flange should be equipped with soft gaskets and fixed bolts and nuts (users can choose to install bolts and nuts).
        For bilateral flange remote transmitters, capillary components and remote flanges should only be installed in the same ambient temperature. The minimum bending radius of the capillary is 75mm, and winding is strictly prohibited!
        6.2 Environmental conditions
        ambient temperature
        Minimum: depending on the filling fluid
        Maximum: 85 ℃
        When equipped with LCD display and fluororubber sealing ring, -20~65 ℃
        Storage temperature/transportation temperature
        Minimum: depending on the filling fluid
        Maximum: 85 ℃
        Relative humidity: 0-100%
        Impact resistance
        Acceleration: 50g
        Duration: 11ms
        Anti vibration
        2g to 500Hz
        Electromagnetic compatibility (EMC)
        See Table 4 "Electromagnetic Compatibility Schedule" on the next page
        6.3 Process Medium Limits
        Temperature limit
        Medium temperature: -30~400 ℃
        Table 3 Relationship between Filling Fluid, Working Temperature, and Minimum Working Static Pressure


        Fill Fluid

        silicone oil

        (S)

        High temperature

        silicone oil(H)

        Ultra high temperature

        silicone oil(U)

        vegetable oil(V)

        density25℃

        960

        kg/m3

        980

        kg/m3

        1020

        kg/m3

        937

        kg/m3

        Working temperature
        Degree range


        -30~

        200℃

        -10~

        350℃

        -10~

        400℃

        0~

        250℃


        temperature

        Working static pressure range (kPa absolute pressure)

        20℃

        >10

        >10

        >10

        >25

        100℃

        >25

        >25

        >25

        >50

        150℃

        >50

        >50

        >50

        >75

        200℃

        >75

        >75

        >75

        >100

        250℃


        >100

        >100

        >100

        350℃


        >100

        >100


        400℃



        >100


        Note: Those exceeding the range of working temperature and static pressure relationship above should be specifically pointed out, and special designs can be used to meet the requirements.
        Transmitter body pressure limit
        From an absolute pressure of 3.5kPa to the rated pressure, the protective pressure can be greater than 1.5 times the rated pressure and applied to both sides of the transmitter.
        Rated pressure of remote transmission flange
        ANSI standard: 150psi~600psi
        DIN standard: PN 1.6MPa~PN 10MPa
        Unidirectional overload limit
        The low pressure side is the rated pressure of the transmitter body, while the high pressure side is the rated pressure of the remote flange, which may cause adjustable zero drift.
        Weight
        Unilateral remote transmission is about 7-10kg for DN 50/2 ", 8-11kg for DN 80/3", and 9-12kg for DN 4 ";
        Bilateral remote transmission is about 10-16.5kg for DN 50/2 ", 12-18kg for DN 80/3", and 14-21kg for DN 4 ".
        Explosion proof performance
        NEPSI Flameproof License: Ex d Ⅱ C T6
        NEPSI Intrinsic Safety License: Ex ia IIC T4
        Permissible operating temperature: -40 ℃~65 ℃
        6.4 Power supply and load conditions
        The power supply voltage is 24V
        R ≤ (Us-12V)/Imax k Ω
        Where Imax=23 mA
        Maximum power supply voltage: 42VDC
        Minimum power supply voltage: 12VDC, 15VDC (backlight LCD display)
        Digital communication load range: 250~600 Ω
        material quality
        Measurement capsule: stainless steel 316L
        Diaphragm: stainless steel 316L, Hastelloy C, tantalum
        Process flange: stainless steel 304
        Filling fluid: silicone oil, high-temperature silicone oil, ultra-high temperature silicone oil, vegetable oil
        Sealing ring: nitrile rubber (NBR), fluororubber (FKM)
        Polytetrafluoroethylene (PTFE)
        Transmitter housing: aluminum alloy material, with epoxy resin sprayed on the surface
        Shell sealing ring: nitrile rubber (NBR)
        Nameplate: stainless steel 304
        Electrical connections
        M20X1.5 cable sealing buckle and wiring terminal are suitable for wires ranging from 0.5 to 2.5mm2.
        Process Connection
        The low pressure side of the transmitter has NPT 1/4 and UNF 7/16 internal threads. The liquid level flange on the high-pressure side of the transmitter complies with ANSI or DIN standards. Can be installed directly, refer to Page 42 Part 7.
        Shell protection level: IP67
        Table 4 Electromagnetic Compatibility Schedule


        Serial Number

        Test items

        Basic standards

        Test conditions

        Performance Level

        1

        Radiated interference (shell)

        GB/T 9254-2008表5

        30MHz~1000MHz

        qualified

        2

        Conducted interference
        (DC power port)


        GB/T 9254-2008表1

        0.15MHz~30MHz

        qualified

        3

        Electrostatic discharge (ESD) immunity

        GB/T 17626.2-2006

        4kV(contact)

        8kV(air)

        B

        4

        Radio frequency electromagnetic

        field immunity

        GB/T 17626.3-2006

        10V/m (80MHz~1GHz)

        A

        5

        Power frequency magnetic

        field immunity

        GB/T 17626.8-2006

        30A/m

        A

        6

        Electrical fast transient pulse

        group immunity

        GB/T 17626.4-2008

        2kV(5/50ns,5kHz)

        B

        7

        Surge immunity

        GB/T 17626.5-2008

        1kV(Between lines)

        2kV(Between lines)

        (1.2us/50us)

        B

        8

        Immunity to conducted interference

        induced by radio frequency fields

        GB/T 17626.6-2008

        3V (150KHz~80MHz)

        A

        Note: (1) A performance level description: During testing, the performance is normal within the technical specification limits.
        (2) B performance level description: During testing, the function or performance is temporarily reduced or lost, but it can recover on its own, and the actual operating status, storage, and data remain unchanged.
        7 Dimensions in millimeters
        Figure 1 Basic bilateral differential pressure remote transmission sealing device diagram



        Figure 2 Basic Single Side Differential Pressure Remote Transmission Sealing Device Diagram

        Note: (1) The unilateral basic differential pressure remote sealing device can be installed on the high-pressure side of the transmitter body or on the low-pressure side of the transmitter;